蘇州天劍服務工程師在用戶現(xiàn)場進行調(diào)試的時候發(fā)現(xiàn)Brocade 300交換機進行過配置,且現(xiàn)任運維管理員也不知道密碼,在取得用戶確認的情況下蘇州天劍服務工程師對Brocade 300交換機密碼進行重置。
由于交換機沒有Reset按鈕,只能通過console使用root賬戶登錄系統(tǒng)進行密碼重置操作。
user: root
password: fibranne
20240117_20:34---FCSW07 login: root
20240117_20:34---Password:
20240117_20:34---
20240117_20:34--------------------------------------------------------------------
20240117_20:34---Disclaimer for Root and Factory Accounts Usage!
20240117_20:34---
20240117_20:34---This Fibre Channel switch is equipped with Root and Factory accounts
20240117_20:34---that are intended for diagnostics and debugging purposes solely by
20240117_20:34---the Equipment vendor's trained engineers. Improper use of the
20240117_20:34---functionality made available through the Root or Factory account could
20240117_20:34---cause significant harm and disruption to the operation of the SAN fabric.
20240117_20:34---
20240117_20:34---Your use of the functionality made available through the Root or Factory
20240117_20:34---account is at your sole risk and you assume all liability resulting from
20240117_20:34---such use. The Equipment vendor shall have no liability for any losses
20240117_20:34---or damages arising from or relating to the use of the Root or Factory
20240117_20:34---account (and the functionality enabled thereby) by anyone other than
20240117_20:34---the Equipment vendor's authorized engineers.
20240117_20:34---
20240117_20:34---Proceeding with the usage of this switch as the Root or Factory user
20240117_20:34---explicitly indicates your agreement to the terms of this disclaimer.
20240117_20:34---
20240117_20:34---Please change passwords for switch default accounts now.
20240117_20:34---Use Control-C to exit or press 'Enter' key to proceed.
20240117_20:34---
20240117_20:34---Password was not changed. Will prompt again at next login
20240117_20:34---until password is changed.
20240117_20:34---FCSW07:root> passwddefault
20240117_20:34---Password policies are already set to default.
20240117_20:34---All account passwords have been successfully set to factory default.
20240117_20:35---FCSW07:root>
20240117_20:35---FCSW07:root>
登錄后使用passwddefault命令進行密碼重置,默認admin用戶密碼為password。
需要注意的是,請盡量不要修改root用戶密碼,一旦root密碼遺忘只能發(fā)回原廠進行處理。